- Open Dripproof and Totally Enclosed Fan Cooled
- Energy Efficient per NEMA (1993) MG1, 12-10
- 140-440T Frames, 1 through 400 Horsepower
- 3600 - 900 rpm / 2 through 8 pole
- Both 60 hertz and 50 hertz operation
- 250 Frame and larger ratings suitable for wye-start delta run or
across-the-line starting
- CE Mark on nameplate
- Meets EPACT 92 (USA), NOM 74 (Mexico), and CSA C390 (Canada) efficiency
levels
Product Overview
U.S. Motors' World Motor® is designed for the global marketplace.
It provides an economical method of meeting evolving efficiency requirements
such as EPACT '92 for the United States, NOM 74 for Mexico and CSA C390 for
Canada. The World Motor a general purpose motor that meets standard NEMA
requirements on 60 hertz operation, including 40°C ambient, Design B, class B
temperature rise at full load and usable up to 3300 ft altitude.
The World Motor is available in open dripproof or totally enclosed fan cooled
designs. Two types of totally enclosed fan cooled motors are available: the
Unimount® or the Hostile Duty®. On 180 frame and larger,
the Unimount frame is constructed from extruded aluminum and the Hostile Duty
models have rugged cast iron frames and end bells. On 56 and 140 frames, both
offer rolled steel shells with aluminum end bells on Unimount and cast iron end
bells on Hostile Duty. Unimount designs also offer removable bases for footless
applications.
Designed for flexibility, the 230/460 or 460 volt 60 hertz motors can be used
on 190/380 or 380 volt 50 Hz. This 50/60 hertz operation is clearly defined on
the dual frequency World Motor nameplate (see example on back cover). The
nameplate also displays the "CE" mark verifying certification to the
European community's low voltage directive.
The World Motor is constructed with all copper windings and low loss stator
laminations to optimize efficiency. This product meets the federally legislated
efficiency levels mandated effective October 24, 1997, in the USA. In addition,
all conduit boxes are diagonally split and oversized from NEMA standards for
ease of installation. The standard F1 position may be easily modified on all 180
frames and above for F2 assembly position when required.
To modify the stock product offerings, we offer several stock conversion
options including: C-face, D-flange, canopy cap/drip cover, terminal block, and
strip heater. In addition we offer a wide variety of features on special factory
orders. For a more comprehensive description of our new line of World Motors
please contact your U.S. Motors sales representative.
Meets North American Efficiency Requirements
- USA - 1997 Federal Efficiency levels - EPACT 92
- Mexico - NOM 74
- Canada - CSA C390
- Efficiency per NEMA MG1, 12-10
Meets International Requirements
- 50 and 60 hertz operation
- Wye-Delta or Across-the-Line Start (250 Frame or larger)
| |
Open Dripproof |
Open Dripproof |
TEFC
Unimount |
TEFC
Hostile Duty |
| Type |
"FD" |
"FR" |
"FUT" |
"FCT" |
| Frame Material |
Steel |
Cast Iron |
Aluminum
(56-140 Rolled Steel) |
Cast Iron
(140 Rolled Steel) |
| End Shield Material |
140-250 Aluminum
280-320 Cast Iron |
Cast Iron |
Aluminum |
Cast Iron |
| Paint |
Corro-Duty
(250 Hour Salt Spray) |
Corro-Duty
(250 hour Salt Spray) |
Corro-Duty
(250 hour Salt Spray) |
Corro-Duty
(250 hour Salt Spray) |
| Horsepower Range |
1/3 thru 60 HP |
30 thru 400 HP |
1 thru 30 HP |
1 thru 200 HP |
| Frame Sizes |
56 thru 320T Frame |
360 thru 449T Frame |
56 thru 286T Frame |
140 thru 447T Frame |
CE Mark on
Nameplate |
Yes |
Yes |
Yes |
Yes |
| Phase |
Three Phase |
Three Phase |
Three Phase |
Three Phase |
| Speeds |
60Hz
50Hz |
3600 - 900rpm |
3600 - 900rpm |
3600 - 900rpm |
3600 - 900rpm |
| 3000 - 750 rpm |
3000 - 750 rpm |
3000 - 750 rpm |
3000 - 750 rpm |
| Voltage |
60Hz
50 Hz |
200, 208-230/460,
460,575 Volt |
200, 230/460,
460,575 Volt |
200, 208-230/460,
460,575 Volt |
200, 208-230/460,
460, 575 Volt |
| 190/380, 380 Volt |
190/380, 380 Volt |
190/380, 380 Volt |
190/380, 380 Volt |
| Hertz |
50/60 hertz on 230/460
volt & 460 volt only,
60Hz on 200 & 575 volt |
50/60 hertz on 230/460
volt & 460 volt only,
60Hz on 200 & 575 volt |
50/60 hertz on 230/460
volt & 460 volt only,
60Hz on 200 & 575 volt |
50/60 hertz on 230/460
volt & 460 volt only,
60Hz on 200 & 575 volt |
| Service Factor |
1.15 on 60 Hz
1.0 on 50 Hz |
1.15 on 60 Hz
1.0 on 50 Hz |
1.25 on 60 Hz
1.0 on 50 Hz |
1.15 on 60 Hz
1.0 on 50 Hz |
Starting Factor
Across-the-Line
Wye-Delta
Part Winding Start* |
56-360T
250-360T
56-360T |
360-449T
360-449T
360-449T |
56-280T
250-280T
56-280T |
56-447T
250-447T
56-447T |
| Bearing Type |
Sealed on 56-140T
Double Shielded
180-320T |
Double Shielded 360T
Open 400-440T |
Sealed on 56-140T
Double Shielded
180-280T |
Double Shielded
140-360T
Open 400-440T |
Regreasing
Provisions |
Yes
180 Frame and larger |
Yes |
Shaft End |
250 Frame
and larger |
|