   40T72 PID Single-display universal temperature   controller
  • Universal input configurable from keyboard.
  • Accuracy better than 0.2% f.s. at nominal conditions.
  • Configuration from service serial line available.
  • Transmitter power supply.
  • Relay, logic or triac control output with heat/cool function.
  • 1 alarm with fully configurable function (up to 3 alarm points)
  • Self-tuning, Auto-tuning, Soft-start
  •  
400-401 Single display controller
  • Universal input configurable from the faceplate
  • Accuracy better than 0,2% f.s. at nominal condition
  • Deviation bargraph indication
  • Control output: relay or logic with Heat/Cool function
  • 1 alarm with configurable function (up to 3 different alarm setpoints)
  • Self-tuning, Auto-tuning, Soft-start, Man/Auto function
  • Possibility to configure the unit by serial line
  • Possibility of auxiliary input for current transformer 50mAac or 3rd alarm output, logic or relay (only 401 mod.)
600 Controller
  • Universal input configurable from faceplate
  • Accuracy better than 0.2% f.s. under nominal conditions
  • Control output: relay, logic, Triac or continuous
  • Hot/cold function with selection of cooling fluid
  • 3 alarms with completely configurable function
  • Analog retransmission output
  • Isolated digital input with configurable function
  • Auxiliary input for CT (TA) (50mAac)
  • Heater break or probe short-circuit alarm
  • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function
  • Double set, set ramp, timed output function
  • Optically isolated RS485 serial line.
    Protocol: GEFRAN CENCAL or MODBUS RTU
  • Self-diagnosis
  • Rapid configuration from PC with Winstrum packet
1200-1300 Configurable controllers
  • Universal input configurable from faceplate
  • Accuracy better than 0.2% f.s. under nominal conditions
  • Control output: relay, logic, Triac or continuous
  • Hot/cold function with selection of cooling fluid
  • 3 alarms with completely configurable function
  • Analog retransmission output
  • Up to 2 isolated digital inputs with configurable function
  • Isolated digital input with configurable function
  • Auxiliary input for CT (TA) (50mAac)
  • Heater break or probe short-circuit alarm
  • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function
  • Double set, set ramp, timed output function
  • Optically isolated RS485 serial line. Protocol: GEFRAN MODBUS RTU
  • Self-diagnosis
  • Rapid configuration from PC with Winstrum packet

 

600 OF “Open Frame” Controller 

Main applications

  • Small industrial ovens
  • Pipe welders
  • Temperature control units
  • Dryers
  • Climatic cells and test benches
  • Control panels with membrane keyboard
Main features
  • Universal input configurable from faceplate
  • Accuracy better than 0.2% f.s. under nominal conditions
  • Up to 5 outputs, relay, logic, for control, alarms
  • Hot/cold function with selection of cooling liquid
  • 3 alarms with completely configurable function
  • Software alarm for load interrupt or probe in short circuit (LBA)
  • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function
  • Double set, set ramp, timed output function
  • Setpoints programmer functions with 3 configurable steps
  • Configurable internal buzzer
  • Optically isolated RS485 serial communication, protocol: MODBUS RTU
  • Self-diagnosis
  • Panel mounting
  • Screw connections with removable terminals

 

 

1000-1001-1101 Configurable controllers
  • Inputs for thermocouples and resistance thermometers completely configurable from the faceplate
  • Offset function on the input signal
  • Relay, mA or logic main output
  • Between 1 and 3 configurable alarms
  • Auxiliary input for C.T.
  • Alarm for open circuit load or short-circuit probe
  • PD alarm output configurable for cooling
  • Self-tuning/Auto-tuning, Soft-start, bumpless Man/Auto transfer
  • Serial line: opt isolated 4-wires

  

800 Controller
  • Universal input configurable from the faceplate
  • Accuracy 0,2% f.s.
  • Two control outputs: relay, logic or analogue with Heat/Cool function
  • 3 configurable alarms
  • 2 analogue outputs
  • 2 digital inputs with configurable function
  • Auxiliary input for C.T. or remote setpoints
  • Heater Break or short-circuit probe alarm
  • Self-tuning, Soft-start, Auto-tuning, Man/Auto, Bumpless, Setpoints, Locale/Remoto
  • Function multi-set, rampa di set, timer
800V Controller for motorized valves
  • Universal input configurable from the faceplate
  • Acquisition of the input signal every 120msec ; resolution 30000steps
  • Two control outputs: relay, logic or analogue with Open/Close valve function
  • 3 configurable alarms
  • 2 analogue outputs (setpoints retransmission)
  • 2 digital inputs with configurable function
  • Auxiliary input for valve position potentiometer feedback
  • Heater Break or short-circuit probe alarm
  • Self and Auto-tuning, Soft-start, Local/Remote setpoints, Auto/Man
  • Multi-set function, timer set ramp
800P Programmer - Controller
  • Universal input configurable from the faceplate
  • Acquisition of the input signal every 120msec ; resolution 30000steps
  • Two control outputs: relay, logic or analogue with Heat/Cool function
  • 3 configurable alarms
  • 2 analogue outputs (setpoints retransmission)
  • 2 digital inputs with configurable function
  • Auxiliary input for C.T. or remote setpoints
  • Heater Break or short-circuit probe alarm
  • Self and Auto-tuning, Soft-start, Local/Remote setpoints, Auto/Man
  • 12 (16) steps arranged in max. 4 programs
  • Second SP retransmitted to a slave controller, with same time-base
1600-1800 Controllers
  • Universal input configurable from the faceplate
  • Acquisition of the input signal every 120msec ; resolution 30000steps
  • Two control outputs: relay, logic or analogue with Heat/Cool function
  • 3 configurable alarms
  • 2 analogue outputs (setpoints retransmission)
  • 2 digital inputs with configurable function
  • Auxiliary input for C.T. or remote setpoints
  • Heater Break or short-circuit probe alarm
  • Self and Auto-tuning, Soft-start, Local/Remote setpoints, Auto/Man
  • Function multi-set, rampa di set, timer
1600-1800V Controllers for motorized valves
  • Universal input configurable from the faceplate
  • Acquisition of the input signal every 120msec ; resolution 30000 steps
  • Two control outputs: relay, logic or analogue with Open/Close valve function
  • 3 configurable alarms
  • 2 analogue outputs (setpoints retransmission)
  • 2 digital inputs with configurable function
  • Auxiliary input for valve position potentiometer feedback
  • Heater Break or short-circuit probe alarm
  • Self and Auto-tuning, Soft-start, Local/Remote setpoints, Auto/Man
  • Multi-set function, timer set ramp
1600-1800P Programmers - Controllers
  • Universal input configurable from the faceplate
  • Acquisition of the input signal every 120msec ; resolution 30000steps
  • Two control outputs: relay, logic or analogue with Heat/Cool function
  • 3 configurable alarms
  • 2 analogue outputs (setpoints retransmission)
  • 2 digital inputs with configurable function
  • Auxiliary input for C.T. or remote setpoints
  • Heater Break or short-circuit probe alarm
  • Self and Auto-tuning, Soft-start, Local/Remote setpoints, Auto/Man
  • 12 (16) steps arranged in max. 4 programs
  • Second SP retransmitted to a slave controller, with same time-base
3400-4400 Configurable controllers
  • Cascade control
  • Ratio control
  • Square root extraction on input signal
  • Programmer with 4 setpoints and 4 ramps
  • Thermocouple or resistance thermometer inputs and linear inputs with configurable scale and linearization
  • Isolated inputs for remote setpoints, valve position feedback signal or load break detection
  • Two control outputs with independent PID parameters (Heat/Cool)
  • AUTO/MAN station with bump less transfer incorporated
  • Configurable output for a retransmission signal
  • Serial line: opt isolated 4-wires configurable. Protocol: GEFRAN CENCAL
3500-4500 Configurable program-controllers
  • Thermocouple, resistance thermometer and linear inputs with configurable scales and characterization
  • Remote setpoints, valve position or load current sensing input (optional)
  • 8 configurable opt isolated digital inputs (optional)
  • 8 configurable opt isolated outputs that may programmed with time (optional)
  • Double independent PID outputs (Heat/Cool)
  • 10 sets of PID tuning parameters to select from for each program step
  • Configurable isolated retransmission output
  • 2...10 configurable alarms
  • Expansion up to 16 relay outputs (optional) (with 2 MD81 units)
  • Serial line: opt isolated 4-wire configurable. Protocol: GEFRAN CENCAL or MODBUS
2500 High Performance Controller
  • Double configurable input for strain gauge / potentiometer / linear signal / TC / RTD
  • Two auxiliary analog inputs
  • Differential measurement
  • High precision: 0.1 % f.s. ± 1 digit
  • Automatic calibration for 6-wire strain gauge
  • Transmitter power supply and strain gauge probe power supply
  • PID controls with 8 sets of selectable parameters
  • 4 configurable alarms, failsafe function
  • Up to 3 isolated analog outputs for control and retransmission
  • 4 digital inputs
  • 4 relay outputs with configurable function
  • Expansion with 4 configurable digital inputs and/or outputs
  • Serial communication interface:
     - RS485/RS 232 MODBUS RTU protocol (optional)
     - Profibus DP Slave (optional)
  • Front panel with three 5-digit displays and two bar graphs
GFXTERMO4 4-zone modular controller

4 universal process inputs
• 4 independent hot/cold PIDs
• 4 main outputs
• 4 auxiliary analog inputs
• 4 configurable outputs: relay / logic / TRIAC / continuous
• 2 configurable relay
• 2 digital inputs
• Standard communication port: Modbus RTU
• Optional port for Fieldbus: Profibus DP, CANopen, DeviceNet, Modbus RTU, Ethernet Modbus TCP
• Installs on DIN rod and panel

Four loop modular power controller

Unit consisting of: 

  • Controller
  • 30, 60, 80kW solid state relay
  • Current transformers (one or four)
  • Fuses-holder (option)
  • 4 universal main inputs
  • 4 heat/cool independent PID
  • 4 main output internally wired to the SSR
  • 4 auxiliary analog inputs (option)
  • 4 configurable output (option):
    relay / logic / TRIAC / continuous
  • 2 configurable relay alarm output
  • 2 digital inputs
  • Standard digital communication:
    Modbus RTU
  • Optional Fieldbus communication:
    Profibus DP, CANopen, DeviceNet,
    Modbus RTU, Ethernet Modbus TCP
  • DIN rail or panel mounting

 

 

Profibus

 

CANopen
DeviceNet

 

Ethernet

 

Modbus
 

Reserved copyright for Gefran


Home / Contact Us / Products / Service / Sales /Supported Product / Powertec Support / Serviced Products / Feedback


 

Microcon Technologies Inc.

1105 Crestlawn Drive, Unit # D8 & D9

Mississauga, Ontario L4W 1A7 Canada

Tel: (905) 602-4770

Fax: (905) 602-4779

e-mail: sales@microcontechnologies.com

Website: www.microcontechnologies.com